FAMILY SELECTOR / 01
Residential
Match the module to usable roof area, mounting requirements and the electrical design.
- Usable roof area
- Mounting interfaces
- Electrical design

PRODUCT FAMILY / Homes · distributed energy
Begin with roof geometry, mounting interfaces and the electrical design. A residential family is a starting point; the exact module is selected with the project team.

01 / INSPECT THE INTERFACES
EA-ZLK-US25-DC25
Rev C · October 2025 · p.2
1812 × 1046 × 40 mm nominal envelope; 21 kg. External dimensions follow the cited company-published record. Confirm the current release before design.
02 / COMPANY-PUBLISHED SOURCE RECORD
| Record | Published value | Inherited source citation and scope |
|---|---|---|
| Controlling specification record | EA-ZLK-US25-DC25 · Rev C · October 2025 · p.2 | Public datasheet · zlk-residential-revc · EA-ZLK-US25-DC25 · Rev C · October 2025 · p.2 |
| Nominal envelope / length | 1812 mm | Public datasheet · zlk-residential-revc · EA-ZLK-US25-DC25 · Rev C · October 2025 · p.2 |
| Nominal envelope / width | 1046 mm | Public datasheet · zlk-residential-revc · EA-ZLK-US25-DC25 · Rev C · October 2025 · p.2 |
| Nominal envelope / depth | 40 mm | Public datasheet · zlk-residential-revc · EA-ZLK-US25-DC25 · Rev C · October 2025 · p.2 |
| Module mass | 21 kg | Public datasheet · zlk-residential-revc · EA-ZLK-US25-DC25 · Rev C · October 2025 · p.2 |
| EA-ZLK7-SHDB108-405/M / STC / power | 405 W | Public datasheet · zlk-residential-revc · EA-ZLK-US25-DC25 · Rev C · October 2025 · p.2 |
| EA-ZLK7-SHDB108-405/M / STC / vmp | 34.9 V | Public datasheet · zlk-residential-revc · EA-ZLK-US25-DC25 · Rev C · October 2025 · p.2 |
| EA-ZLK7-SHDB108-405/M / STC / imp | 11.61 A | Public datasheet · zlk-residential-revc · EA-ZLK-US25-DC25 · Rev C · October 2025 · p.2 |
| EA-ZLK7-SHDB108-405/M / STC / voc | 40.7 V | Public datasheet · zlk-residential-revc · EA-ZLK-US25-DC25 · Rev C · October 2025 · p.2 |
| EA-ZLK7-SHDB108-405/M / STC / isc | 12.62 A | Public datasheet · zlk-residential-revc · EA-ZLK-US25-DC25 · Rev C · October 2025 · p.2 |
| EA-ZLK7-SHDB108-410/M / STC / power | 410 W | Public datasheet · zlk-residential-revc · EA-ZLK-US25-DC25 · Rev C · October 2025 · p.2 |
| EA-ZLK7-SHDB108-410/M / STC / vmp | 35.1 V | Public datasheet · zlk-residential-revc · EA-ZLK-US25-DC25 · Rev C · October 2025 · p.2 |
| EA-ZLK7-SHDB108-410/M / STC / imp | 11.68 A | Public datasheet · zlk-residential-revc · EA-ZLK-US25-DC25 · Rev C · October 2025 · p.2 |
| EA-ZLK7-SHDB108-410/M / STC / voc | 40.7 V | Public datasheet · zlk-residential-revc · EA-ZLK-US25-DC25 · Rev C · October 2025 · p.2 |
| EA-ZLK7-SHDB108-410/M / STC / isc | 12.63 A | Public datasheet · zlk-residential-revc · EA-ZLK-US25-DC25 · Rev C · October 2025 · p.2 |
| EA-ZLK7-SHDB108-415/M / STC / power | 415 W | Public datasheet · zlk-residential-revc · EA-ZLK-US25-DC25 · Rev C · October 2025 · p.2 |
| EA-ZLK7-SHDB108-415/M / STC / vmp | 35.3 V | Public datasheet · zlk-residential-revc · EA-ZLK-US25-DC25 · Rev C · October 2025 · p.2 |
| EA-ZLK7-SHDB108-415/M / STC / imp | 11.75 A | Public datasheet · zlk-residential-revc · EA-ZLK-US25-DC25 · Rev C · October 2025 · p.2 |
| EA-ZLK7-SHDB108-415/M / STC / voc | 40.7 V | Public datasheet · zlk-residential-revc · EA-ZLK-US25-DC25 · Rev C · October 2025 · p.2 |
| EA-ZLK7-SHDB108-415/M / STC / isc | 12.64 A | Public datasheet · zlk-residential-revc · EA-ZLK-US25-DC25 · Rev C · October 2025 · p.2 |
| Front glass | 3.2 mm AR-coated tempered glass | Public datasheet · zlk-residential-revc · EA-ZLK-US25-DC25 · Rev C · October 2025 · p.2 |
| Frame | 6005-T5 aluminum · 40 mm depth | Public datasheet · zlk-residential-revc · EA-ZLK-US25-DC25 · Rev C · October 2025 · p.2 |
| Finish | Anodized coating · 10–15 μm | Public datasheet · zlk-residential-revc · EA-ZLK-US25-DC25 · Rev C · October 2025 · p.2 |
| Junction box | IP68 · 3 bypass diodes | Public datasheet · zlk-residential-revc · EA-ZLK-US25-DC25 · Rev C · October 2025 · p.2 |
| Connector | Stäubli MC4-Evo 2 | Public datasheet · zlk-residential-revc · EA-ZLK-US25-DC25 · Rev C · October 2025 · p.2 |
| Cable | 1200 mm, as specified in Rev C | Public datasheet · zlk-residential-revc · EA-ZLK-US25-DC25 · Rev C · October 2025 · p.2 |
| Maximum system voltage | 1000 V | Public datasheet · zlk-residential-revc · EA-ZLK-US25-DC25 · Rev C · October 2025 · p.2 |
| Maximum series fuse | 25 A | Public datasheet · zlk-residential-revc · EA-ZLK-US25-DC25 · Rev C · October 2025 · p.2 |
| Pmax coefficient | −0.27 %/°C | Public datasheet · zlk-residential-revc · EA-ZLK-US25-DC25 · Rev C · October 2025 · p.2 |
| Voc coefficient | −0.24 %/°C | Public datasheet · zlk-residential-revc · EA-ZLK-US25-DC25 · Rev C · October 2025 · p.2 |
| Isc coefficient | +0.06 %/°C | Public datasheet · zlk-residential-revc · EA-ZLK-US25-DC25 · Rev C · October 2025 · p.2 |
03 / ENGINEERING CONTEXT
The original six engineering chapters are retained with their source context. Treat source-dependent claims as company-published until the applicable current record is reviewed.
01 / Origin
The Rev C construction specifies AR-coated tempered glass and a 6005-T5 aluminum frame. Supplier and lot records establish material origin for the selected article.
EA-ZLK-US25-DC25 · Rev C · October 2025 · p.2
02 / R&D
Centauri Renewable Corporation controls the R&D direction presented here. Device studies remain separate from the released residential model and its specification.
Research → design review → configuration record
03 / Architecture
Explore the 1812 × 1046 × 40 mm nominal envelope, the optical surface, frame and electrical interfaces in the model studio. Internal layer geometry remains illustrative.
405–415 W at STC · selected Rev C power bin
04 / Manufacture
Follow assembly, lamination, framing and electrical connections through the applicable drawings and work instructions. The selected manufacturing lot carries its own origin records.
Configuration → assembly → lot traceability
05 / Inspect
Connect dimensional and electrical inspection to the exact model. Review installation interfaces, certification coverage and warranty terms for the project.
Exact model → accepted results → applicable documents
06 / Application
Carry the selected residential model into a rooftop concept. Review usable roof area, shading, electrical requirements and local installation conditions.
Concept → engineering → delivery → commissioning
NEXT STEP
Share the application, design constraints and expected purchasing timeline. No order is created by preparing an inquiry.